و,ثنائي الفينيل متعدد الكلور, تخصيص PCBA وPECVD, النماذج الأولية والتصنيع المنتج

تحميل | عن | اتصال | خريطة الموقع

Ventilator PCB Assembly

اسم: Ventilator PCB Assembly

الركيزة: FR4

سمك النحاس: 1 أوقية

سمك اللوحة: 1.6مم

Minimum hole size: 0.2مم

الحد الأدنى لعرض الخط: 3ml

Minimum line spacing: 3ml

Finish: 3ml

حجم اللوحة: customized

Product Name: PCB/PCBA Component Prototype

مادة: FR4/Aluminum/Ceramic CEM1

  • تفاصيل المنتج

Definition and Functionality

A ventilator is a medical device designed to assist individuals who are unable to breathe independently. It delivers oxygen to the lungs and removes carbon dioxide, crucial for patients with respiratory issues. The ventilator comprises a compressible air reservoir, an oxygen supply, a breathing tube, and multiple printed circuit board assemblies (PCBAs) that manage airflow and monitor the ventilator’s functions.

Importance in Modern Medicine

Ventilators are vital in modern medicine, playing a crucial role in preventing and treating respiratory failure, reducing complications, and saving lives. They are widely used in various respiratory conditions, anesthesia management during surgery, and emergency resuscitation.

Classification of Ventilators

By Type of Use or Application

(1) Controlled Mechanical Ventilation (CMV)

  • Definition: Breathing is entirely controlled by the ventilator when spontaneous breathing is absent or weakened.
  • Applicability: Diseases causing loss or weakening of spontaneous breathing.

(2) Assisted Mechanical Ventilation (AMV)

  • Definition: Ventilator assists spontaneous breathing.
  • Applicability: Weak spontaneous breathing requiring support.

By Route of Use

  • (1) Intrathoracic or Airway Compression Type
  • (2) Chest Appearance Type

By Switching Mode of Inhalation and Exhalation

  • (1) Constant Pressure Type
  • (2) Volume-Fixed Type
  • (3) Timing Type
  • (4) Mixed Type (Multifunctional Type)

By Ventilation Frequency

  • (1) High-Frequency Ventilation: >60 times/min
  • (2) Constant Frequency Ventilation: <60 times/min

By Synchronization Device

  • (1) Synchronous Ventilator: Triggers with spontaneous breathing.
  • (2) Asynchronous Ventilator: Used for controlled mechanical ventilation.

By Applicable Object

  • (1) Baby Ventilator
  • (2) Children Ventilator
  • (3) Adult Ventilator

By Working Principle

  • (1) Simple Ventilator
  • (2) Membrane Lung Ventilator

Modes and Functions of Mechanical Ventilation

Primary Modes

(1) Intermittent Positive Pressure Ventilation (IPPV)

  • مبدأ العمل: Positive pressure during inhalation, zero pressure during exhalation.
  • Clinical Application: Patients with respiratory failure.

(2) Intermittent Positive and Negative Pressure Ventilation (IPNPV)

  • مبدأ العمل: Positive pressure during inhalation, negative pressure during exhalation.
  • Clinical Application: Causes alveolar collapse.

(3) Continuous Positive Airway Pressure (CPAP)

  • مبدأ العمل: Positive airway pressure throughout the respiratory cycle.
  • Advantages: Reduces inspiratory effort, prevents alveolar collapse.
  • العيوب: Disturbs circulation, causes barotrauma.

(4) Intermittent Mandatory Ventilation and Synchronized Intermittent Mandatory Ventilation (IMV/SIMV)

  • IMV: No synchronization, time-based ventilation.
  • SIMV: Synchronized ventilation with spontaneous breathing.
  • Advantages: Reduces ventilator dependence, better for weaning.
  • طلب: Used during weaning.

(5) Mandatory Minute Ventilation (MMV)

  • مبدأ العمل: Adjusts ventilation to meet preset minute ventilation.

(6) Pressure Support Ventilation (PSV)

  • Definition: Pressure support during spontaneous inhalation.
  • مبدأ العمل: Starts with inhalation, ends with exhalation.
  • طلب: Used with SIMV for weaning.

(7) Volume Support Ventilation (VSV)

  • مبدأ العمل: Patient-triggered, supports to achieve desired tidal volume.

(8) Biphasic or Bilevel Positive Pressure Ventilation

  • مبدأ العمل: Different pressures for inhalation (P1) and exhalation (P2).
  • Clinical Application: Versatile, can simulate IPPV, CPAP, and SIMV.

Secondary Functions

(1) End-Inspiratory Pause

  • Function: Holds breath at end of inspiration.
  • Clinical Application: Enhances gas distribution and drug delivery.

(2) Positive End-Expiratory Pressure (PEEP)

  • Function: Maintains positive airway pressure at end of exhalation.
  • Clinical Application: Treats hypoxemia due to intrapulmonary shunt.

Development and Applications

(1) Microcomputerization

  • سمات: Self-test, alarm functions, special features like suction and atomization.

(2) Monitoring Function

  • Key Aspects: Displays ventilation and lung mechanics parameters, trends, and logs.

(3) Ventilator Mode Developments

  • Innovations: Autonomous pressure modes, closed-loop ventilation, BiPAP.

(4) Adjustment and Safety

  • سمات: Single-knob adjustment, digital parameter setting, safety ranges.

(5) Purchasing Principles

  • Considerations: Ventilator grade, hospital needs, user experience, and resource utilization.

Our Services

We provide Ventilator PCB Assembly and printed circuit board assemblies services. UGPCB is your one-stop Turnkey PCB Assembly factory.

السابق:

التالي:

ترك الرد

ترك رسالة