Thermal Properties
Glass Transition Temperature (Tg)
- Method: IPC-TM-650 2.4.25
- Condition: DSC
- Unit: Degree Celsius
- Typical Value: 135
Thermal Decomposition Temperature (Td)
- Method: IPC-TM-650 2.4.24.6
- Condition: 5% Weight Loss
- Unit: Degree Celsius
- Typical Value: 310
Coefficient of Thermal Expansion (CTE)
- Pre Tg: IPC-TM-650 2.4.24, Before Tg, ppm/Degree Celsius, 55
- Post Tg: IPC-TM-650 2.4.24, After Tg, ppm/Degree Celsius, 308
- 50-260 Degree Celsius: %, 4.5
Thermal Stress Testing
- Method: IPC-TM-650 2.4.24.13
- Condition: 288 Degree Celsius, Solder Dip
- Result: No Delamination after 100S
Electrical Properties
Volume Resistivity
- After Moisture Resistance: IPC-TM-650 2.5.17.1, MΩ·cm, 5.0E + 08
- E-24/125: MΩ·cm, 5.0E + 06
Surface Resistivity
- After Moisture Resistance: IPC-TM-650 2.5.17.1, MΩ, 5.0E + 07
- E-24/125: MΩ, 5.0E + 06
Arc Resistance
- Method: IPC-TM-650 2.5.1
- Condition: D-48/50+D-4/23
- Unit: s
- Typical Value: 126
Dielectric Breakdown
- Method: IPC-TM-650 2.5.6
- Condition: D-48/50+D-4/23
- Unit: kV
- Typical Value: 60
Dissipation Factors
Dissipation Constant (Dk)
- 1MHz: IPC-TM-650 2.5.5.9, –, 4.7
- IEC 61189-2-721: –, –
Dissipation Factor (Df)
- 1MHz: IPC-TM-650 2.5.5.9, –, 0.016
- IEC 61189-2-721: –, –
Mechanical Properties
Peel Strength (1oz HTE Copper Foil)
- Initial: IPC-TM-650 2.4.8, N/mm, –
- After Thermal Stress: IPC-TM-650 2.4.8, N/mm, 1.8
- At 125 Degree Celsius: N/mm, 1.6
Flexural Strength
- LW: IPC-TM-650 2.4.4, A, MPa, 550
- CW: IPC-TM-650 2.4.4, A, MPa, 450
Other Properties
Water Absorption
- Method: IPC-TM-650 2.6.2.1
- Condition: E-1/105_D-24/23
- Unit: %
- Typical Value: 0.10
Comparative Tracking Index (CTI)
- Standard: IEC60112
- Rating: PLC 0
Flammability
- UL94: C-48/23/50, Rating V-0
- E-24/125: Rating V-0
Remarks and Explanations
- Specification Sheet: IPC-4101/21, for reference only.
- Basis of Typical Values: Based on a 1.6mm specimen; Tg applicable for specimens ≥0.50mm.
- Data Rights & Details: For detailed information, contact Shengyi Technology Co., Ltd. All rights reserved.
Conditions Explanation
- C: Humidity conditioning
- D: Immersion conditioning in distilled water
- E: Temperature conditioning
- Digits Following Letters: First digit = preconditioning duration (hours), second digit = preconditioning temperature (°C), third digit = relative humidity.